Files

Download poster

Download Poster (792 KB)

Description

Introduction and Objective

  • Impella is a temporary ventricular support device intended for short term use (CP, and ≤ 6 days for Impella 5.0 and LD).
  • There has yet to be a study investigating the outcomes of microaxial support for patients who previously underwent heart transplantation.
  • We aimed to assess utilization patterns of microaxial mechanical circulatory support after heart transplantation in adults and adolescents.

Publication Date

9-19-2022

Keywords

impella, heart transplant, microaxial

Disciplines

Medicine and Health Sciences | Surgery

Comments

Presented at the 67th American Society for Artificial Internal Organs in Chicago, IL.

Microaxial Support After Orthotopic Heart Transplantation