Highlights:
- Pump thrombosis commonly presents with hemolysis and device parameter fluctuations.
- Left atrial compression presents similarly to pump thrombosis but with no device fluctuations.
- Reference standard imaging test for ventricular device thrombus is contrast-enhanced CT.
Recommended Citation
Ruge, Max Rug; Zivan, Tal; Leong, Ron; Feduska, Eric; Shah, Mahek; Rame, J. Eduardo; Massey, Howard; Alvarez, René J; Brailvosky, Yevgeniy; and Rajapreyar, Indranee, "Acute Left Atrial Compression after Ventricular Assist Device Placement" (2022). Division of Internal Medicine Faculty Papers & Presentations. Paper 49.
https://jdc.jefferson.edu/internalfp/49
Creative Commons License
This work is licensed under a Creative Commons Attribution-Noncommercial-No Derivative Works 4.0 License.
Language
English
Comments
This is the final published version of the article from the journal Cardiovascular Imaging Case Reports, Feb. 17, 2022
The article can also be found on the journal's website; https://doi.org/10.1016/j.case.2022.01.008
Copyright: The American Society of Echocardiograph